Evaluation of MRI-based MAGIC polymer gel dosimeter in small photon fields

(2016) Evaluation of MRI-based MAGIC polymer gel dosimeter in small photon fields. International Journal of Radiation Research.

Full text not available from this repository.

Official URL: https://www.scopus.com/inward/record.uri?eid=2-s2....

Abstract

Background: Accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (SRS) and intensity modulated radiotherapy (IMRT). Precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. In the present work the MAGIC polymer gel was used for dosimetry of small circular photon beams. The results of MAGIC were compared with EBT2 measurements and Monte Carlo (MC) calculations. Materials and Methods: Experimental measurements were made by mentioned dosimeters in four small field sizes 5, 10, 20 and 30 mm. The BEAMnrc code based on EGSnrc was used for simulation to calculate dosimetric parameters at these small fields. The phantoms were irradiated in a 6 MV photon beam Varian 2100C linear accelerator at SSD=100 cm. gel readout performed by 3 Tesla MRI scanner. Results: The results showed that the Percent depth dose (PDD) values measured and calculated by EBT2 film and MC had maximum local differences 4 and 5 with PDD values measured by MAGIC for field size of 5mm respectively. These differences decreased for larger field sizes. The measurements of output factor and penumbra (80-20) and (90-10) showed good agreement between the measurements and MC calculation. Conclusion: This study showed that the MAGIC polymer gel based on high resolution MRI images is useful detector for small field dosimetry but its agreement with MC is less than agreement of EBT2 film with MC.

Item Type: Article
Keywords: polymer, Article; controlled study; dose calculation; dosimeter; dosimetry; film dosimeter; gel; irradiation; Monte Carlo method; nuclear magnetic resonance imaging; nuclear magnetic resonance scanner; photon; radiation depth dose; radiation field; radiology phantom
Page Range: pp. 57-63
Journal or Publication Title: International Journal of Radiation Research
Volume: 14
Number: 1
Publisher: Novim Medical Radiation Institute
Identification Number: 10.7508/ijrr.2016.01.009
ISSN: 23454229
Depositing User: مهندس جمال محمودپور
URI: http://eprints.muk.ac.ir/id/eprint/683

Actions (login required)